NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 09/20/01
rp ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: .AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Proj ect/Slte: 40 Rector Street, 40 Rector St., NY, NY TEM Sample No.: SS37 - 55307
Lobby & 16th Floor
Date Received:09/20/01 Grid Openings Analyzed:__ 4
Project Sample No.: 03 Average Grid Opening: 106.CO um
Air Volume: 1800 liters Total Area Analyzed: 0.0450 mm2
Filter Type: KCE 25 mra diam. Pore Size: 0.45 urn Analytical Sensitivity:2nj s/mm2
Effective Area: 385 mm2 0,0048 s/cc
" '1
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5ura Struct/mm2 Struct/cc ngm/m3
f.1
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
"“t
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
Roman Peysakhov Michael A. Gorycki, Ph.D.
rn
Director of Electron Microscopy
NYC-WTC_000237361