NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 09/25/01
ASBESTOS FIBER ANALYSIS' BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
I With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
L-J
Project/Site: 40 Rector Street, ■40 Rector St., NY, NY TEM Sample No.; 5554 - 59468
r") Floors 19^18,J^ 9. 8
Cate Received: 09/24/01 Grid Openings Analyzed.:__ 6
Project Sample No.: 09-24-27 Average Grid Opening: 106.00 um
Air Volume: 1290 liters. Total Area Analyzed :£.:0674 nim2
' Filter Type: MCE 25 mm diam. Pore Size: 0.45'um Analytical Sensitivity: 14.8 s/mm2
, Effective Area: 385 mTn2 0■0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed . CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct. > = 5um 2truct/mTn2 Struct/cc nq-Tn/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000. 0
f. A
Ambiguous 0 0 0 • 0 0 0 0.0 0.0000 0
Total' asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Won-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
1 Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
)’ Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
LJ
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
n Director of Electron Microscopy
f 0
NYC-WTC_000237340
OCR can misread numbers and units. Confirm readings against the page image before using them.