NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New Yprk 10010
ATC Associates Inc. Approved N.Y'. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
LJ New York, NY 10010 Report Date: 09/25/01
ASBESTOS FIBER TkNALYSIS BY TRANSMISSION'ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: 7iHER7i Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
: Semple Identification Analysis Parameters
Project/Site: 40 Rector Street, 40 Rector St., MY, NY TEM Sample No.: 5554 59447
r---.
Z1oo?:s19£1Lj10,9jS
Date Received: 09/24/01 Grid Openings Analyzed;__ 5
Project Sanple Mo.: 09-24-06 Average Grid Opening: 106.QO um
Air Volume ;],M01iters Total Area Analyzed: 0.0562 mm2
Filter Type: MCE 25 mm diam.. Pore Size: 0,4.5 um Analytical Sensitivity
Effective Area; 385 mm2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
fl
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct. >=5um Struct/Tnm2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 C
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 C.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
’ Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. ,
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy