NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos air analysis results, 40 Rector Street, Sep 2001

Machine-extracted title · confidence 95%

Laboratory report documenting asbestos fiber analysis by TEM for air samples from floors 5-7 at 40 Rector Street dated September 28, 2001.

NYC-WTC_000237301
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

(■'■'I

ATC Environmental, Inc. <. 104 East 25th Street New York, New York 10010 ATC Associates Inc. Approved N.Y. State ELAP #10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY 10010 Report Date: 09/28/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EFA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Sits: 40 J;ector Streeti J^Yj NY TEM Sample No.: 5573 - 59623 Floors 5-7 Date Received: 09/28/^ Grid Openings Analyzed:__ 6

Project Sample No.: 07 Average Grid Opening: 106.00 um

Air Volume:^^50 liters Total Area Analyzed.•0^067£mrn2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 14,8 s/mm2 Effective Area: 385 mm2 0.0046 s/cc

FIBROUS PARTICULATES ANALYZED Humber Observed CONCENTRATION Total Single Matrix . Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um ' Struct/rnm2 Struct/cc ngm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0 y,J Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A-

n Totals (All Structures) 0 0 0.0 0.0000 N/A

u The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected The Tinalysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

n

NYC-WTC_000237301

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000237301Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →