NYC 9/11 Public Portal Document
-
ATC Environmental, Inc.
n 104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
U New York, NY 10010 Report Date; 09/28/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHSRA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: £0^£ctnr Streetj NYj NY. TEM Sample No.: 5573 - 59622
\ Floors 5-7
Date Received; 09/28/01 Grid Openings Analyzed:__ 6
Project Sample No.: 06 Average Grid Opening: 106.00 unt
Air Volume: 1250 liters ' Total Area Analyzed: 0.0674 mm2
Filter T-ype: MCE 25 mm dlam., Pore Size: 0.45 urn Analytical Sensitivity: 14.8 s/rTim2
Effective Area :38£mm2 0.0046 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. struct. Filter Air
Fibers Bundles Clusters Struct. Stirrct. >=5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
■ Ambiguous 0 0 0 0 0 0 0. 0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 c.c 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
f.1 Analyzed by: Report Reviewed by;
'I
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC_000237300