NYC 9/11 Public Portal Document
GJ
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
■-.J
ATC Associates Inc. Approved N.Y. State ELAP #10879
n 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 09/28/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
with Fiber Identification by Selected-Area Electron Diffraction (SABD) and Energy-Dispersive X-RAY Spectroscopy (EDS)
UJ
Method: MERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Cd
Sample Identification AnalvsisParainet^^
uJ
Project/Site: 40 Rector Street, NY, NY TEM Sample No.: 5573 - 59621
Floors 5-7
Date Received: 09/28/01 Grid Openings Analyzed;__ 6
Project Sample No . :__05 Average Grid Opening: 106.00 uro
Air Volume : 125(3 liters Total Area Analyzed; 0.0674 mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 14.8 s/mm2
Effective Area: 385 rom2 0.0046 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5um Struct/ram2 Struct/cc n.om/m3
Chrysotile Asbestos . 0 0 0 1 1 • 0 14.8 0.0046 151
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 1 0 14.8 0.0046 151
Non-Asbestos 0 0 0 0 •0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0 . 0000 N/A
Totals (All Structures) 1 0 14.8 0.0046 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
n Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Uj
ro Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
L.J
NYC-WTC_000237299