NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 09/28/01
r ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
with Fiber Identification by Selected-Area Electron Diffraction iSAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFH, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: 40 Rector Street,.NY^ NY TEM Sample No.: 5574 - 59645
Floors 15-17
Date Received: 09/28/Dl Grid Openings Analyzed:__ 6
C Project Sample No. : T28 Average Grid Opening: 106.00 urn
* Air Volume: 1280 liters Total Area Analyzed: 0.0674 mm2
Filter Type: MCE 25 mm dlain. , Pore Size: 0.45' urn Tknalytical Sensitivity: 14.8 s/mm2
Effective Area: 3 85 mni2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
single Matrix Total. Struct. Filter Air
Fibers BundTes Clusters Struct;Struc^ >=5um £truct/mra2 Struct/cc ngm/mS
Chrysotile Asbestos 0 0 1 1 2 1 29.7 0.0089 294
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 2 1 29.7 0.0089 294
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/ft
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 2 1 29.7 0.0089 N/A
The.estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
' Amphibole Asbestos Type: None detected .
The Analysis was carried but in accordance with the approved TEM method.
n This laboratory is in compliance with'the quality specified for the method.
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
LU
NYC-WTC_000237280
OCR can misread numbers and units. Confirm readings against the page image before using them.