NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 09/28/01
fuj ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
with Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Ruis, EPA Federal Register (40 CPR, Part 763), Vol. 52, No. 210, October 39, 1987
f3
: Sample Identification Analysis Parameters
Project/Site: 40 Rector Street, NY, NY TEI^ Sample No. : 5574 - 59643
Floors 15-17
Date Received09/28/01 • Grid Openings Analyzed:__ 6
r- Project Sample No. Average Grid Opening: 106.00 um
Air Volums: 1280 liters Total Area Analyzed:^^^^674 rnm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 14.8 s/mm2
Effective Area: 365 mm2 0.D04S s/cc
y ------ ------ :------ ---- .--- ------------------
; FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
single Matrix ' Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct =5um Struct/mTn2 Struct/cc ngm/m3
Chrysotile Asbestos 0 •0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 - 0 0 0 0 0.0 0.0000 N/A
No Ident i f i c at ion 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED); None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
U-)
CI Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
Ui
NYC-WTC_000237278