NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
U
ATC Associates Inc. Approved N.Y. State ELAP #10879
n 104 East 25th Street ACCREDITED NVLAP Lab Code #1187
New York, NY 10010 Report Date: 09/28/01
Pi ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
' Sample Identification Analysis Parameters
Project/Site-. 40 Rector Street, NY, NY TEM Sample No.: 5574 - 59637
Floors 15-17
Date Received: 09/28/01 Grid Openings Analyzed:__ 6
Project Sample Nc.: TOS Average Grid Opening: 106,00 urn
Air Volume: 128C liters Total Area Analyzed: 0.0674 mm2
Filter Type; MCE 25 mm diam,, Pore Size: 0.45 um Analytical Sensitivity; 14.8 s/mm2
Effective Area: 3 85 mrri2 0■0045 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total, Struct, Filter Air
~ Fibers Bundles Clusters Struct. Struct = 5um Struct/mm2 Struct/cc nqm/m3
i 1 Chrysotile Asbestos 0 0 0 0 0 0 0.0 0. 0000 0
Amphibole Asbestos . 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestqs 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 • N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D. ,
Director of Electron Microscopy
NYC-WTC_000237275