NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
LJ
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
I J New York, NY 10010 Report Date: 09/28/01
n ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
u With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, ERA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
i Sample Identification Analysis Parameters
Project/Site: 40 Rector Street, NY, NY' TEM Sample No.; 5575 - 59657
Floorsl2&J^
Date Received: 09/28/01 Grid Openings Analyzed:__ 6
Project Sample Wo.: TIP Average Grid Opening: 106.00 um
Air Volume: 1260 liters Total Area Analyzed: 0,0674 mm2
Filter Type: MCE 25 mm diam., Pore Size; 0.45 um Analytical Sensitivity; 14.8 s/mm2
Effective Area; 385 mm2 0.00.45 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Strucu. >=5unt Struct/n'.m2 Struct/cc nqtn/mS
Chrysotile Asbestos 0 0 0 0 0 0 • 0.0 C.OOOO 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 C.C 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
0 The Amphibole Asbestos Type: None detected
Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: : Report Reviewed by:
n
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
! „.J
rn
NYC-WTC_000237255