NYC 9/11 Public Portal Document
lJ
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 09/28/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method.: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
n ' ■
i Sample Identification Analysis Parameters
Project/Site: 40 Rector Street, NY, NY TEM Sample No,: 5575 - 59653
! Floors 12 & 14
( j Date Received Grid Openings Analyzed:__ 6
Project Sample No.; TQ6 Average Grid Opening: 106.00 um
Air Volume: 1270 liters . Total Area Analyzed: 0.0674 mm2
Filter Type: MCE 25 mm diam.. Pore Size; 0.45 urn Analytical Sensitivity: 14.8 s/inm2
Effective Area: 385 mn^ 0.0045 s/cG
n ----- ---------------------- - -----
FIBROUS PARTICULATES ANALYZED
Number Obseir/ed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers' Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
f—)
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 O'. 0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.c 0.0000 N/A
O Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated, uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i. d. (EDS/SAED) : None detected
• j Tkmphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
A This laboratory is in compliance with the quality specified for the method.
u
Analyzed by: Report Reviewed by:
uJ
Roman Peysakhov Michael A. Gorycki, Ph.D.
R Director of Electron Microscopy
R
NYC-WTC_000237253