NYC 9/11 Public Portal Document
r-’A
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
Uj New York, NY 10010 Report Date: 09/29/01
n ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
with Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
LU .
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
' Sample Identification Analysis Parameters
Project/Site: 40 Rector Street, NY, NY TEM Sample No.: 5579 - 59753
Foors07j3,4,n^2,VLob^
Date Received: 09/29/01 Grid Openings Analyzed:__ 6
Project Sample No. :T30 Average Grid Opening: 106.00 um
Air Volume :1260 nAt^^ Total Area Analyzed: 0.0674 mTn2
Filter Type: MCE 25 mm diam., Pore Size; 0.45 um Analytical Sensitivity: 14.8 s/mm?,
Effective Area: 385mm2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct. > = 5um Struct/inin2 Struct/cc nqm/ra3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 c
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
Ko Identification 0 0 0 0 0 0 0.0 0.0000 . N/A
Totals (All Structures) 0 0 0. 0 0.0000 N/A
The estimated uncertainty of this.analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
■
NYC-WTC_000237208