NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
.ATC Associates Inc. Approved N.Y. State ELAP #10879
n 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 09/29/01
n asbestos fiber analysis by TRANSMISSION ELECTRON MICROSCOPY (TEM)
: Kith Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method; AHBRA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
r/; Sample Identification Analysis Parameters
Project/Site: 40 Rector Street, NY. NY TEM Sample No.: 5579 - 59748
U Foors 6j7j 3j 4jlij2jl/l£b^
Date Received: 0°/29/01 Grid Openings Analyzed:__ 6
Project Sample No.: T25 Average Grid Opening: 106.00 um
Air Volume: 1270 liters Total Area Analyzed: 0.0674 mm2
Filter Type: MCE 25 mm diam., Pore Size; 0.45 urn Analytical'Sensitivity: 14.8 s/mm2
LJ Effective Area: 385 inm2 0.0045 s/cc
i FIBROUS---
PARTICULATES ANALYZED
-----;--------------- —
Number Observed CONCENTRATION
Total
Single Matrix Total- Struct. Filter Air
Fibers Bundles Clusters Struct. Struct. >=5um Struct/mm2 Struct/cc ncrm/ms
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
r7
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
■ The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
n This laboratory is in compliance with the quality specified for the method.
Analyzed by; Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
n Director of Electron Microscopy
NYC-WTC_000237203