NYC 9/11 Public Portal Document
104 East 25th Street
dftTC ASSOCIATES INC.
New York, New York 10010
www.atc-enviro.com
212.353.8280
Fax 212.353.8306
December 27, 2001
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Toxic Organic Compounds
P. S.89M
ATC Project No. 15-19125-0297
Dear Mr. Orlan;
ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for toxic
organic compounds conducted on December 15, 2001, at the referenced school. The New York
City Board of Education (BOE) requested this sampling at the recommendation of Environ Corp.,
the consultant to the parents association.
On each day, ATC collected four (4) air samples for toxic organic compounds (TOC) at specified
locations. Samples were collected for a minimum of one hundred minutes using Supelco®
sampling tubes connected to battery-powered sampling pumps at a flow rate of 0.15 liters per
minute. Pumps were calibrated before and after each sampling period. Two (2) samples were
collected inside the building and two (2) were collected outside. The sample tubes were prepared
and analyzed by PSC Analytical Services, Inc., an American Industrial Hygiene Association-
accredited laboratory in Reading, PA. Analysis was performed by gas chromatography/mass
spectrometry according to EPA Method TO-l/TO-2 (TO-17).
Each sample was analyzed for a panel of twenty-three (23) specific TOCs. These compounds
were: acrylonitrile, allyl chloride, benzene, bromobenzene, carbon tetrachloride, chlorobenzene,
chloroform, cumene, 1, 2-dichloroethane, 1, 2-dichloropropane, 1, 3-dichloropropane, ethyl
benzene, ethylene dibromide, heptane, 1-heptene, methylene chloride, tetrachloroethene, toluene,
1,1, 1-trichloroethane, trichloroethene, vinylidene chloride, vinyl chloride and xylenes.
In addition, unidentified peaks on the cluomatogmni were compared against the mass
spectrograph’s library of organic compounds (“library search”) for possible identification..
The sampling locations were specified by the parents association consultant. They were: the
hallway by the cafeteria, Room 202, outdoors in the playgi'ound and the roof by the air intake.
TOC Panel Results ■
Five of the TOCs in the panel were detected in the samples. Unknown peaks were also found in
each sample. The TOCs identified from the panel are shown in Table 1. A copy of the analytical
report is provided in Attachment 1.
CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008 CITY_21 MC100_014660231
NYC-WTC_000237108
OCR can misread numbers and units. Confirm readings against the page image before using them.