NYC 9/11 Public Portal Document
Summary of Respirable Particulate (PM2.5) Measurements at PS/IS 89
Made by ATC for the Board of Education
24-Hour Gravimetric
Number of Range of PM2.5 Number of Number of Particulate Measurements
Readings Measurements Average Measurements Measurement Made inside PS 89^’^
(Inside/Outsi (ug/m’) PM2.5 above 40 ug/m' s above 65 (ug/m^)
(D)
de/*’ Measurement ug/m’
(C)
Date
(ug/m’)
zz====
February 72 inside 14 to 39 (inside) 29 (inside) 0 (inside) 0 (inside)
21, 2002 8 outside 83 to 91 (outside) 87 (outside) 8 (outside) 8 (outside)
February 72 inside 19 to 36 (inside) 24 (inside) 0 (inside) 0 (inside)
20, 2002 8 outside 45 to 50 (outside) 47 (outside) 8 (outside) 0 (outside)
i—— I'-l III
February 72 inside 12 to 29 (inside) 18 (inside) 0 (inside) 0 (inside)
19, 2002 8 outside 32 to 42 (outside) 36 (outside) 2 (outside) 0 (outside)
Number of instantaneous measurements of respirable particulate matter, commonly called PM2.5, which is
the concentration in air of particles finer than 2.5 micrometers in diameter. Readings are made both inside
and outside of PS/IS 89, typically between 8 am and 4 pm.
Range (minimum to maximum concentration) of instantaneous respirable particulate measurements made
inside and outside of PS/IS 89 on that day.
Average of all the instantaneous respirable particulate readings made inside and outside of PS/IS 89 on that
day.
Number of instantaneous measurements that were above the USEPA guideline of 40 ug/m^ as a 24-hour
average concentration for sensitive groups, including children, the elderly, and people with heart or lung
disease.
Number of instantaneous measurements that were above the USEPA ambient air quality standard of 65
ug/m^ as a 24-hour average concentration for the general population.
The results of gravimetric particulate measurements made by filtering air through a filter for a 24 hour
period. The filter is then submitted to a laboratory for analysis of the particulate concentration. The 24-hour
sampling period typically begins in the morning of this day and extends until the morning of the following day.
ATC has begun making instantaneous particulate measurements at schools and other locations away from
lower Manhattan as a basis for comparison with measurements made at PS/IS 89. This column summarizes the
minimum and maximum particulate levels measured at these other locations, along with the number of
measurement locations.
A:\PS89 2-25.doc 3 02/26/02 3:45 PM
CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008 CITY_21MC100_014659826
NYC-WTC_000236855
OCR can misread numbers and units. Confirm readings against the page image before using them.