Twentieth Floor Clean-up Report
3.0 SAMPLING AND ANALYSIS
3.1 Air
TRC conducted air sampling to evaluate air quality, and determine if areas were fit for re
occupancy. Sample results are attached in Appendix B, Data Tables. The following
identifies the sampling and analysis that was conducted along with associated standards
and guidelines:
Asbestos in Air - Asbestos air sampling was conducted to determine airborne
concentrations outside the work area. The sampling was performed using National
Institute of Occupational Safety and Health (NIOSH) method 7400. Samples were
analyzed by Phase Contrast Microscopy (PCM). Sample results were compared to a post
cleaning target concentration of less than O.Olfibers per cubic centimeter of air.
• Lead in Air - Lead in air samples were collected by NIOSH method 7300. The samples
were sent to EMSL Laboratories for analysis. EMSL is an independently owned and
operated laboratory accredited by New York State Department of Health. Samples were
analyzed by NIOSH Method 7082. Sample results were compared to a post-cleaning
target concentration of less than 50 micrograms per cubic centimeter of air.
3.2 DUST
TRC conducted lead wipe and microvacuum sampling of residual dust to confirm the
effectiveness of the response actions. TRC sampled hard surfaced items such as metal
ducts, ceiling tiles, desks, bookshelves, file cabinets. The following identifies the
sampling and analysis that was conducted along with associated standards and guidelines:
• Asbestos in Dust - Dust sampling was conducted utilizing American Society for Testing
and Materials (ASTM) Test Method D5755-95 Microvacuum Sampling and Indirect
Analysis (Filter Sample Analysis) of Dust by Transmission Electron Microscopy (TEM)
2 TRC
Customer-focused Solutions
NYC-WTC_000236598