SciLab 202021886
> ■*
Z Client nUt TRC Environmental Corporation
o Table I 5
I
io Summary of Transmission Electron Microscopy (TEM) Results for Asbestos (air)
35052-0000-00007; NYC Law Dept; 100 Church St/ OSHA
co
o
o
o
Structure Structure 6
ro Air Area * Analytical Asbestos Structures Detected Density Concentration Type o
o
cn
CD
cn
SciLab
Sample #
01
Client
Sample #
GS-STEL-2902-0505
Dilution Filtered Analyzed Sensitivity
Factor (liters) (sq. mm.) (struc/cc air)
60 .1 0.0642
0.5-5.0
0.0
(Microns)
>5.0
0.0
Total
0.0
(struc/sq. mm.)
>5.0
<10
Total
<10
(struc/cc air)
>5.0 Total
<0.0642 <0.0642
of
Asbestos
NSD
I
02
03**
Ceasar Rodriguez
GS-STEL-2902-0506
Daniel Reilly
GS-STEL-2902-0507
60 .1 0.0642 0.0 0.0 0.0 <10 <10 <0.0642 <0.0642 NSD
I
Field Blank
04** GS-STEL-2902-0508
Field Blank
o
__ L
o * concentration represented by the detection of 1 structure
o
e
cn
** not analyzed
NSD: No Asbestos Structures Detected Reviewed By: ; Analyzed By:,