NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

PCM fiber results, 100 Church Street, Oct 2001

Machine-extracted title · confidence 95%

Lab report documenting PCM fiber analysis for OSHA compliance at 100 Church Street.

NYC-WTC_000235573
Page image
Scanned page image, NYC-WTC_000235573
OCR text

OCR status: ok · source: pdftotext

w NYC 9/11 Public Portal Document

Sci b#: 202022146 Client Name; TRC Environmental Corporation P 1 of 1

Phase Contrast Microscopy (PCM) Fiber Results 35052-0000-00007; NYC Law Dept; 100 Church Street/OSHA Flow Air Fiber Fibers SciLab Client Rate Duration Filtered Density Cone. Fields Fibers TWA Sample # Sample # / Location Collected (Hters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)

01 GS-OSHA-21202-0517 2/12/02 2 300 600 100 50 63.69 0.041 Miguel Rynoso 02 GS-OSHA-21202-0518 2/12/02 2.5 270 675 100 18 22.93 0.013 Miguel Rynoso 03 GS-OSHA-21202-0601 2/12/02 2 300 600 100 21 26.75 0.017 Kyle Jones 04 GS-OSHA-21202-0602 2/12/02 2.5 270 675 100 7 8.92 0.005 Kyle Jones 05 GS-OSHA-21202-#1 2/12/02 0 0 0 100 0.5 0.64 Field Blank Footnotes: 1 06 GS-OSHA-21202-#2 2/12/02 0 0 0 100 0.5 0.64 Field Blank Footnotes: 1 Reporting Notes: (1) Fibers/cc cannot be jOlflWat^or sanJpW(or bl^s) with no air volume. Analyzed by: Marvin Brothers 1 j I : Date Analyzed: 2/13/02 Samples analyzed by NIOSH 74CW(A) Method, Issue #2,' 8/15/94; Limit of Detections 5.5 fibers per 100 fields or 7 fibers/mm2; This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA=Not Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=O.4O5, Interlab Sr=0.45, New York samples (NYSDpH ELAP Lab # 11480): National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.

NYC-WTC_000235573

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235573Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →