Sci b#; 202021514 Pa of 1'
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; N.Y.C. Law Dept.; 100 Church Street, N.Y, N.Y. OSHA
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Fields Fibers Density Cone. TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm ) (Fibers/cc)
01 GS-OSHA-0401 2/6/02 2 660 1320 100 8 10.19 0.003
Joshua F. Sample
02 GS-OSHA-0402 2/6/02 2 660 1320 100 4 5.10 < 0.002
Daniel Reilly's Sample
03 GS-OSHA-0403 2/6/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
04 GS-OSHA-0404 2/6/02 0 0 0 100 0.5 0.64
Blank Footnotes: J
Reporting Notes;
(1) Fibers/cc cannot be calculated fm samples (or blanks) with no air volume.
Analyzed by: Devin Ahyee^_____ Date Analyzed; 2/6/02
Samples analyzed by NIOSH 7400(A) Method, Issfle #2, 8/15/94: Limit of Detections 5.5 fibers per 100 fields or 7 fibers/mm2; This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: NDsNo fibers observed: NA= Not
Analyzed; Walton-Beckelt graticle field area = 0.00785 mm2.' TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.