Sci b#: 202032753 P 1 of 1
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York Law Department; 100 Church Street/Ambient
Flow Air Fiber Fibers
SciLab Client Date Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-3/16/02-ASB-0207 3/16/02 5 240 1200 too 5.5 7.01 0.002
Rm 2-151
02 GS-3/16/02-ASB-0208 3/16/02 5 240 1200 100 2 2.55 < 0.002
Rm 2-154
03 GS-3/16/02-ASB-0209 3/16/02 5 300 1500 100 5.5 7.01 0.002
Ws 2-156b
04 GS-3/16/02-ASB-0210 3/16/02 5 300 1500 100 2 2.55 < 0.002
Rm 2-162
05 GS-3/16/02-ASB-0211 3/16/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: 1
06 GS-3/16/02-ASB-0212 3/16/02 0 0 0 100 0.5 0.64
Field Blank Footnotes; 1
Reporting Notes: )
(1) Fibers/cc cannot be>^CTl^d (or blanks) with no air volume.
Analyzed by: Tatyana Date Analyzed: 3/18/02
Samples analyzed by NIOSH Mem^riStIC'727^15/94: Limit of Detection^ 5.5 fibers per 100 fields or 7 fibers/mni2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480); National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.
NYC-WTC_000235537