NYC 9/11 Public Portal Document
vx
Sci Ob#: 202022972
Client Name: TRC Environmental Corporation
Phase Contrast MicroscoDvlPCMiFiberResults
35052-0000-00007; New York City Law Department; 100 Church Street AMBIENT
Flow Air Fiber Fibers
SciLab Client Date Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/nun^ ) (Fibers/cc)
01 GS-ASB-21902-0415 2/19/02 5 120 600 100 2 2.55 < 0.004
4th Floor Room 4-154
02 GS-ASB-21902-0416 2/19/02 5 120 600 100 1 1.27 < 0.004
4th Floor Room 4-315
03 GS-ASB-21902-0674 2/19/02 5 210 1050 100 2 2.55 < 0.003
4th Floor Room 6-177
04 GS-ASB-21902-0507 2/19/02 5 240 1200 100 2 2.55 < 0.002
5th Floor Hallway (east)
05 GS-ASB-21902-0508 2/19/02 5 240 1200 100 3 3.82 < 0.002
5 th Floor Hallway (west)
06 GS-ASB-21902-0201 2/19/02 5 180 900 100 9 11.46 0.005
Room 2-103
07 GS-ASB-21902-0202 2/19/02 5 180 900 100 2 2.55 < 0.003
Room 2-114
08 GS-ASB-21902-0203 2/19/02 5 180 900 100 3 3.82 < 0.003
Room 2-135
09 GS-ASB-21902-B1 2/19/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
10 GS-ASB-21902-B2 2/19/02 0 0 0 100 0.5 0.64
Blank Footnotes: /
Reporting Notes:
(1) Fibers/cc cannot b«rt^culQ^for ^attmles (or blanks) with no air volume.
Analyzed by: Marvin BrothersV H ■ \ Analyzed: 2/20/02
Samples analyzed by NIOSH 7400(A) Method, Issue #2. 8/15/94: Limit of Detections 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed; NA= Not
Analyzed; Walton-Beckett graticle field area = 0,00785 mini: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
deteraiine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr=0.405, Interlab St=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.
NYC-WTC_000235505
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235505Source: NYC Law Department, mirrored locally