SciUfrjob #; 202022697
Client Name; TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York city Law Department; 100 Church St./ Ambient
Flow Au- Fiber Fibers
SciLab Client Date Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm ) (Fibers/cc)
01 GS-21502-ASB-0501 2/15/02 5 180 900 100 1 1.27 < 0.003
5th Hoor At Rm 5-161
02 GS-21502-ASB-0301 2/15/02 5 150 750 100 1 1.27 < 0.004
3rd Floor At Rm 3-206
03 GS-21502-ASB-B1 2/15/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: I
04 GS-21502-ASB-B2 2/15/02 0 0 0 100 0.5 0.64
Feild Blank Footnotes: 1
Reporting Notes:
(1) Fibers/cc cannot bef«glciil^^ for skm^s (or blanks) with no air volume.
Analyzed by: Marvin Brothers I A Date Analyzed; 2/18/02
Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94; Limit of Detection= 5.5 fibers per 100 fields or 7 Cbers/mm2: "This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480); National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory.. AIHA # 102843.
NYC-WTC_000235503
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235503Source: NYC Law Department, mirrored locally