Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street/ Ambient
Flow Air Fiber Fibers
SciLab Client Date Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected (iiters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-ASB-21402-0668 2/14/02 5 300 1500 100 1 1.27 < 0.002
AtRm6-187
02 GS-ASB-21402-0669 2/14/02 5 300 1500 100 1.5 1.91 < 0.002
At Rm - 6 - 170
03 GS-ASB-21402-0670 2/14/02 5 270 1350 100 2 2.55 < 0.002
At Rm 5 - 222
04 GS-ASB-21402-0671 2/14/02 5 270 1350 100 2 2.55 < 0.002
At Rm 6 - 206
05 GS-ASB-21402-0672 2/14/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: 1
06 GS-ASB-21402-0673 2/14/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: J
Reporting Notes:
(1) Fibers/cc cannot be calcined for samnfts (o/blaite) with no air volume.
Analyzed by: Lance Tuckniskye ---- YArWIic Analyzed; 2/15/02
Samples analyzed by NIOSH 740{J(A) Method, Issue#!, 8/15/94: LiDifl of Detection= 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed; NA=Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2; TWA Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.