Carpet Air Sample Data Table, Jan-Feb 2002

Machine-extracted title · confidence 90%

Table of air samples taken from carpet surfaces at the NYC Law Department building between late January and early February 2002.

NYC-WTC_000235468–000235472
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 3 Air Samples - Carpet OSHA STEL New York City Law Department 100 Church Street New York

Sample ID: STEL0318 STEL0319 STEL0322 STEL0323 STEL0326 STELO326 STEL0330 STEL0331 STEL0334 STEL0335 STEL0338 STEL0339 STEL0342 STEL0343 STEL0346 STEL0347 Lab Sample ID : 1 2 1 2 1 2 1 2 1 2 1 2 1 2 2 Sample Date: 3/4/02 3/4/02 3/5/02 3/5/02 3/6/02 3/6/02 3/7/02 3r7IQ2 3/8/02 3/8/02 3/9/02 3/9/02 3/11/02 3/11/02 3/12/02 3/12/02 Start Time: 12:45 12:46 13:00 13:01 9:00 9:30 9:00 9:01 8:30 8:32 13:30 13:31 7:30 7:31 10:00 10:04 Sample Type: Air Air Air Air Air Air Air Air Air Air Air Air Air Air Air Air Floor:

Kenneth Wilfredo Ceasar Wilson Jose Ceasar Fabien Wilson Wilson Ramon Miguel Manuel Name of Personnel: Jose Ramon Minor Ramirez Rodriguez Bueno Adorino Rodriguez Pereyra Mike Green Bueno Mike Green Bueno Mante Luis Bueno Reynoso Gonzalez

ASBESTOS (fibers/cc) <0.045 <0.045 0.057 <0.045 <0.046 <0.045 <0.045 <0.045 <0.045 <0.022 <0.045 <0.045 <0.045 <0.045 <0.045 <0.045

TEM Quality Controf

ASBESTOS (structures/mm^) NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS <10 NQCS NQCS NQCS NQCS NQCS NQCS

< Indicates (ess (han (he limit of quantification 70 s AHERA re-occupancy criteria for school chiWren NQCS s No quality control sample taken NA s Not Analyzed (1) Analyst was unable to quantify fiber concentration because of overloading of paniculate matter on the finer. (2) Moderate to heavy paniculate matter is present on the finer which may obscure some fibers causing resuns with a low bias. <

Page 4 of 5 TWC Customer-Focused Solutions

NYC-WTC_000235471

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235471Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000235456

Table of air samples taken from carpet surfaces at the NYC Law Department building between late January and early February 2002.

Similar indexed content

NYC-WTC_000235444

Table of ambient air sample data collected at the NYC Law Department building between January and February 2002.

Similar indexed content

Compare copies and versions →