Carpet Air Sample Data Table, Jan-Feb 2002

Machine-extracted title · confidence 90%

Table of air samples taken from carpet surfaces at the NYC Law Department building between late January and early February 2002.

NYC-WTC_000235468–000235472
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 3 Air Samples • Carpet OSHA STEL New York City Law Department 100 Church Street New York

Sample ID: STEL0614 STEL0615 STEL0618 STEL0619 STEL0622 STEL0623 STEL0514 STEL0515 STEL0302 STEL0303 STEL0303 STEL0304 STEL0305 STEL0306 STEL0314 STEL0315 Lab Sample ID: 1 2 1 2 1 2 1 2 2 1 2 1 2 1 2 Sample Date: 2/21/02 2/21/02 2J22/02 2/22/02 2/25/02 2/25/02 • 2/26/02 2/26/02 2/27/02 2/27/02 2f2eiQ2 2/28/02 3/1/02 3/1/02 3/2/02 3/2/02 Start Time: 10:30 10:31 13:30 13:31 15:00 15:01 13:00 13:32 12:45 12:46 14:00 14:01 13:00 13:01 8:00 8:01 Sample Type: Air Air Air Air Air Air Air Air Air Air Air Air Air Air Air Air Floor:

Manuel Jose Ceasar Ruben Kyle Anthony Ceasat Manolo Wilson Jose Jose Ceasar Wilfredo Loading Loading Name of Personnel: Gonzalez Adorino Rodriguez Reyes Johnson Lindsey Rodriguez Alies Beuno Adorino Adorino Rodriguez Jose Ramon Ramirez Dock - East Dock - West

ASBESTOS (fibers/cc) <0.046 <0.022 (1) 0) <0.045 <0.045 <0.045 <0.045 <0.045 <0.045 0.049 <0.045 <0.045 <0.045 <0.045 <0.045

TEM Quality Control

ASBESTOS (stnjctures/mm^) NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS

< Indicates less than the limit of quantification 70 structures/mm’s ahERA re-occupancy criteria for school children NQCS = No quality control sample taken NA = Not Analyzed (1) Analyst was unable to quantify fiber concentration because of ovefiosding of particulate matter on the filter. (2) Moderate to heavy particulate matter is present on the fitter which may obscure some fibers causing results with a low bias.

Page 3 of 5 TRC Customer-Focused Solutions

NYC-WTC_000235470

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235470Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000235456

Table of air samples taken from carpet surfaces at the NYC Law Department building between late January and early February 2002.

Similar indexed content

NYC-WTC_000235444

Table of ambient air sample data collected at the NYC Law Department building between January and February 2002.

Similar indexed content

Compare copies and versions →