Table 1 Air Samples - Carpet Area Air Samples New York City Law Department 100 Church Street New York

• Sample ID: GSASB0365 GSASB0366 GSASB0367 GSASB0368 GSASB0201 GSASB0202 GSASB0203 GSASB0204 GSASB0207 GSASB0208 GSASB0209 GSASB0210 Lab Sample ID: 1 2 3 4 1 2 3 4 1 2 3 4 Sample Date: 3/14/02 3/14/02 3/14/02 3/14/02 3/15/02 3/15/02 3/15/02 3/15/02 3/16/02 3/16/02 3/16/02 3/16/02 Start Time: 8:00 8:01 12:15 12:16 7:00 9:00 12:30 12:45 8:00 8:30 9:00 10:00 * Sample Type: Air Air Air Air Air Air Air Air Air Air Air Air Floor 3 3 3 3 3 3 3 3 3 3 3 3

Location: Room 3-224 Room 3-230 Room 3-179 Room 3-316 Room 2-170 Room 2-173 Room 2-177 Room 2-179 Room 2-151 Room 2-154 Room 2-156b Room 2-162

ASBESTOS (fibers/cc) 0.015(4) 0.018(4) <0.002 0.006 (4) <0.002 <0.002 <0.002 <0.002 0.002 <0.002 0.002 <0.002

TEM Quality Control

ASBESTOS (stRjctures/mm^) <10 <10 NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS

< Indicates less than the limit of quantification. 70 struetures/mm^ = AHERA reoccupancy criteria for school children NQCS = No quality control sample taken NA » Not Analyzed <1) Analyst was unable to quantify fiber concentration because of overloading of particulate matter on the filter. (2) See Asbestos Indoor TEM for TEM result (3) Filter damaged (4) Moderate to heavy particulate matter is present on the fitter which may obscure some fibers causing results with a low bias.

Page 12 of 12 TRC Customer-Focused Solutions

NYC-WTC_000235455

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235455Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000235468

Table of air samples taken from carpet surfaces at the NYC Law Department building between late January and early February 2002.

Similar indexed content

NYC-WTC_000235456

Table of air samples taken from carpet surfaces at the NYC Law Department building between late January and early February 2002.

Similar indexed content

Compare copies and versions →