Table 1
Air Samples - Carpet
Area Air Samples
New York City Law Department
100 Church Street
New York
• Sample ID: GSASB0502 GSASB0503 GSASB0504 GSASB0662 GSASB0663 GSASB0662 GSASB0658 6SASB0659 GSASB0663 GSASB0664 GSASB0665 GSASB0668 GSAS60669 GSASB0670 GSASB0671
Lab Sample ID: 2 3 4 1 2 1 1 2 2 3 4 1 2 3 4
Sample Date; 2/9/02 2/9/02 2/9/02 2/12/02 2/12/02 2/13/02 2/12/02 2/12/02 2/13/02 2/13/02 2/13/02 2/14/02 2/14/02 2/14/02 2/14/02
Start Time: 10:31 12:30 12:31 10:00 10:01 10:00 14:00 14:01 10:10 14:30 14:35 8:00 8:02 14:00 14:03
• Sample Type: Air Air Air Air Air Air Air Air Air Air Air Air Air Air Air
Floor 5 5 5 5 5 6 6 6 6 6 6 6 6 5 6
At WS 5- At WS 5- At Room 5- At Room 5- At Room 5- At WS6- At Room 6- At Room 6- At WS 6- At WS 6- At Room 6- At Room 6- At Room 5- At Room 6-
Location: 147a 157a 141 110 101 leia 240 247 At WS 6-140 173a 5125 187 170 222 206
ASBESTOS (fibers/cc) <0.004 <0.004 <0.004 0.014 0.015 0.016(2) NA NA <0.002 <0.002 <0.002 <0.002 <0.002 <0.002 <0.002
< Indicates less than the limit of quantirication.
70 stmcturee/mn? = AHERA re-occupancy
criteria (or school children
NQCS s No quality control sample taken
NA s Not Analyzed
(1) Analyst was unable to quantify fiber
concentration because of overloading of
particulate matter on the filter.
(2) See Asbestos Indoor TEW for TEM result
(3) Filter damaged
(4) Moderate to heavy partictlale matter is
present on the filter which may obscure some
fibers causing results with a low bias.