Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street / OSHA
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (Hters/min.) (min.) (liters) (Fibers/mm'^ ) (Fibers/cc)
01 GS-3/1/02-OSHA-STEL- 3/1/2002 2 30 60 100 0.5 0.64 < 0.045
Josc Ranion-STEL-0305
02 GS-3/1/02-OSHA-STEL- 3/1/2002 2 30 60 100 3 3.82 < 0.045
Wilfredo Ramirez-STEL-0306
03 GS-3/1/02-OSHA-STEL- 3/1/2002 0 0 0 100 0.5 0.64
Blank-Bl Footnotes: /
04 GS-3/1/02-OSHA-STEL- 3/1/2002 0 0 0 100 0.5 0.64
Blank-B2 Footnotes: /
Reporting Notes:
(1) Fibers/cc cannot beeegcuj les/ar «) with no air volume.
Analyzed by: Anthony Hinton^/^:^^ Date Analyzed: 3/2/2002
Samples analyzed by NIOSH 74(X)(A) M«(hod, Itsue#2, 8/15/94: Limit of Detection= 5.5 fibers per 100 fields or 7 fibers/mni2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not
Analyzed: Walton-Beckett graticle field area3TT00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCLto
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.