Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; N.Y.C. Law Dept.; 100 Church Street, New York (OSHA)
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone.
Fields Fibers
Sample # Sample#/Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-OSHA-0401 2/6/02 2 30 60 100 8 10.19 0,065
Joshua Figueroa's S.T.E.L.
02 GS-OSHA-0402 2/6/02 2 30 60 100 10 12.74 0.082
Daniel Reilly's S.T.E.L.
03 GS-OSHA-0403 2/6/02 0 0 0 100 0.5 0.64
Blank Footnotes: /
04 GS-OSHA-0404 2/6/02 0 0 0 100 0.5 0.64
Blank Footnotes: /
Reporting Notes:
(1) Fibers/cc cannot^calculat^ for samples (or blanks) with no air volume.
Analyzed by: Devin Ahvee5? ; Date Analyzed: 2/6/02
Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94; Limit of Detection= 3.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to tlie sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed; NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2; TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.
o
c
s
o
o
I
o
to
CJi
cn
CD
to
CD
NYC-WTC_000235356
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235356Source: NYC Law Department, mirrored locally