NYC 9/11 Public Portal Document r Sci II ob#; 202023226 Client Name; TRC Environmental Corporation Phase Contrast Microscopy (PCM) Fiber Results 35052-0000-00007; New York City Law Department; 100 Church Street, AMBIENT Flow Air Fiber Fibers SciLab Client Rate Duration Filtered Density Cone. TWA Fields Fibers Sample # Sample # / Location Collected (liters/min.) (rain.) (liters) (Fibers/mm 2 ) (Fibers/cc)

01 GS-022002-ASB-0509 2/20/02 5 240 1200 100 21 26.75 0.009 Sth Floor 02 GS-022002-ASB-0204 2/20/02 5 240 1200 100 2 2.55 < 0.002 2nd Floor Rm 314 03 GS-022O02-ASB-02O5 2/20/02 5 240 1200 100 27 34.39 0.011 2nd Floor Rm 318 04 GS-022002-ASB-0675 2/20/02 5 300 1500 100 28 35.67 0.009 6th Floor Northeast Side Of Hallway 05 GS-022002-ASB-0676 2/20/02 5 300 1500 100 32 40.76 0.010 6th Floor-Northwest Side Of Hallway 06 GS-022002-ASB-B1 2/20/02 0 0 0 100 0.5 0.64 Blank Footnotes: J 07 GS-0220O2-ASB-B2 2/20/02 0 0 0 100 0.5 0.64 Blank Footnotes: 1 Reporting Notes: (1) Fibers/cc cannot bwOfltaild^^oi^aAgfls for blanks) with no air volume. Analyzed by: Marvin Rmthers^ V ) ; Date Analyzed: 2/22/02 Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94: Limit of Detections 5.5 fibers per 100 fields or 7 ribers/nun2: This report relates ONLY to the sample analysis expressed as fibers/sq mni of filter area; ND=No fibers observed: NA= Not Analyzed; Walton-Beckett graticle field area = 0.00785 mini; TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainly of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOHELAP Lab# 11480): National Institute of Standards and Technology Accreditation requirements mandate tliat this report must not be reproduced except in full without the approval of tlic laboratory. AEHA # 102843.

o H I 1-4

R o I o

Ol cn

CaJ O

NYC-WTC_000235208

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235208Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →