NYC 9/11 Public Portal Document
Sci ob#: 202022147 r UI
Client Name; TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; NYC Law Dept.; 100 Church Street/ Ambient
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample#/Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-ASB-21202-0662 2/12/02 5 420 2100 100 60 76.43 0.014
At Rm 5-110
02 GS-ASB-21202-0663 2/12/02 5 420 2100 100 65 82.80 0.015
At Rm 5-101
03 GS-ASB-21202-0664 2/12/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: /
04 GS-ASB-21202-0665 2/12/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: /
Reporting Notes:
(1) Fibers/cc cannot sarjLl^tor blanliks) with no air volume.
Analyzed by: Marvin Brothers 1) * \ \ Date Analyzed; 2/13/02
Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94: Limit of DetecGon= 5.5 fibers per 100 fields or 7 fibers/nim2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area; ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 iir period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sn=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory, AEHA # 102843.