NYC 9/11 Public Portal Document
sample area
TEM Asbestos (dust) Count Sheet analyzed
Client Name: TRC Environmental Corporation
Job #: 202011869 Volume (milliters): 50
Lab Sample #: 24 Dust Sample Area: 100
Client Sample #: SN011102MVAIR0604 Filter Type / Filter Area: MCE 214 nim2
Received: 01/12/2002 09:33:47 Grid Opening Size: 0.01 553
Date Analyzed: 01/15/2002 Area Examined: 0.10000 mna2
Scope #: Dilution Factor: 0.0200 Magnification: 20,000
Accelerating Voltage: 100 KeV
Analysis Performed by:
Aleksandr Barengolts
location Grid Length Width
Opening Fiber /tM gM Fiber Type Morphology EDS Orient. SAED Photo
B2-3/6B 1 1 1 0.1 Chrysotile Fiber Mg, Si, Fe \
B2-3/6C 2 1 2.6 0.1 Chrysotile Fiber Mg, Si, Fe I 1^
B2-3/6E 3 1,1 0.6-9 0.1 Chrysotile B/F/M Mg, Si, Fe 1^
B2-3/6F 4 1 19 0.1 Chrysotile Fiber Mg, Si, Fe / 1^
B2-3/6G 5 NSD U
B2-3/6H 6 NSD U
B3-4/4C 7 1,1 3-15 0.1 Chrysotile Fibe- Mg, Si, Fe 1^
B3-4/4E 8 4,2 0.6-14 0.1-0.3 Chrysotile B/F/M Mg, Si, Fe * 1^
B3-4/4F 9 NSD u
•4/4G 10 NSD u
NSD: No Asbestos Structures Detected
Comments:
Structure Density Grid Evaluation
Total Grid Openings: 10 (str/sq mm) KI Grid Openings Covered > 50%
Chrysotile Asbestos Structures: 13 130.0 KI Intact Grid Opening > 50%
Amphibole Asbestos Structures: 0 <10 KI Undissolved Filter < 10%
Asbestos Structures >=5 microns; 5 50.0 K Folded Replica < 50%'
Total Asbestos Structures: 13 130.0 K Filter Loading < 25%
Analytical Sensitivity: 10 K Particulate Even
CITY_21 MCI 00_014547338