NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 21 pages

NYC-WTC_000232639

Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000232639–000232659
Page image
Scanned page image, NYC-WTC_000232648
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Final Report 125 Cedar Street, NYC, NY

Wipe Sampling

Background and clearance wipe sampling was performed consistent with generally accepted industrial hygiene practices. All acceptable results of the sampling represent conditions found on the dates the samples were collected. Individual analytes specified herein were analyzed in accordance with the project specifications utilizing the following analytical procedures:

• Lead, EPA Method SW-846-6010B • PAHs, ASTM-6661-01, EPA Method SW-846-8270C • Dioxin, ASTM-6661-01, EPA Method SW-846-8290 • Mercury, EPA Method SW-846-7471A

Wipe Sample analysis

Lead ATC’s New York City laboratory performed atomic absorption spectroscopy (AAS) to determine the presence of lead in clearance wipe samples. In elemental foim, lead will absorb ultraviolet light at a specific wavelength when excited by heat. ATC’s AAS instrument looks for the presence of lead by focusing a beam of uv light at a specific wavelength through a flame and into a detector. The wipe sample is aspirated into the flame. If that metal is present in the sample, it will absorb some of the light, thus reducing its intensity. The instrument measures the change in intensity. A computer data system converts the change in intensity into an absorbance.

As concentration goes up, absorbance goes up. The analyst can then construct a calibration curve by running standards of various concentrations on the AAS and observing the absorbance.

PAH Method 8270 was used to quantitate polyaromatic hydrocarbon compounds that are soluble in methylene chloride and capable of being eluted, without derivatization, as sharp peaks from a gas chromatographic fused-silica capillary column coated with slightly polar silicone.

Dioxin The analytical method calls for the use of high-resolution gas chromatography and high- resolution mass spectrometry (HRGC/HRMS) on purified sample extracts. Samples containing concentrations of specific congeneric analytes (PCDDs and PCDFs) considered within the scope of this method that are greater than ten times the upper MCLs must be analyzed by a protocol designed for such concentration levels, e.g.. Method 8280. An optional method for reporting the analytical results using a 2,3,7,8-TCDD toxicity equivalency factor (TEE) was also conducted. However, in accordance with a request made by the USEPA, all non-detect congeners were reported at 50% of the analytical sensitivity, thereby

ATC Project No. 15.22906.0002 Page?

CITY_21MC100_009480312

NYC-WTC_000232648

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000232648Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →