35 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000232249
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000232249–000232281
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
The data from the Dust Monitors will be recorded by CSI CR510 digital data loggers, and telemetered back via CDMA cellular modems. The loggers on-board the units will act as backup to the CSI loggers.
5.1.2 USEPA Reference Method PMjoMonitor
One reference method PMio sampler will be collocated along side the real-time PMio monitors as a quality assurance (QA) check. The sampler will rotate on a monthly basis through all real-time PMio monitor locations for the duration of the monitoring program. It is proposed that a filter based PMIO EPA Reference Sampler be used such as an Andersen RAAS or performance equivalent system. In this manner the 24-hour average PMIO concentration (ug/m3) measured gravimetrically using the filter collection method can be directly compared to the average PMIO concentration measured using the collocated EBAM sampling system. The latter value will be expressed as a 24-hour average representing a composite of all 5-minute average values.
5.2 Asbestos
Asbestos sample collection will be performed in accordance with NIOSH 7402, “Asbestos by TEM”. Asbestos analysis will be performed utilizing Transmission Electron Microscopy (TEM) analysis specified in 40 CFR Part 763, Asbestos Hazard Emergency Response Act, (AHERA), with the following modifications:
• The sensitivity on TEM air samples will be less than 0.002 s/cc. • Both length and width of all asbestos fibers will be recorded. • Confirmation by Energy Dispersive Spectroscopy (EDS) and/or Selected Area Electron Diffraction (SAED) will be performed for each sample. • The morphology of the fibers will be noted and recorded.
5.3 Metals
• Metals sampling and analysis will be performed following EPA Reference Methods for the collection of Total Suspended Particulate (TSP) and lead (40 CFR Part 50 App B) in combination with EPA Method 10 3.3 for the analyses of metals by X-Ray fluorescence.
• Metals to be analyzed by XRF and reported are: Antimony, Barium, Beryllium, Cadmium, Chromium, Copper, Lead, Manganese, Nickel and Zinc.
5.4 Mercury (GasA/apor)
Real-time monitoring foiv mercury will be performed utilizing a Lumex RA 915+ direct read instrument. The readings will be included with the daily download of sample collection data.
The Lumex RA 915+ will be utilized to obtain detection levels below established site air contaminant criteria. At a minimum, mercury readings will be taken twice a shift at each of the fixed air monitoring locations (seven during Abatement Phase and Demolition Phases). At the
L2005-149 (051205) 3 5023623.2
C ITY_D E P_WO RB Y_C AN N ATA_SU B P_000114894
NYC-WTC_000232263
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
Filed elsewhere
NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
19 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162890
Technical discussion regarding discrepancies in NIOSH method flow rates and requirements for large sample volumes at 114 Liberty Street.
9 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155430
Technical correspondence addressing asbestos air sampling methodology and pump flow rate specifications.
9 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000134132
US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
34 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156050
Document tracking the chain of custody for environmental samples collected at 114 Liberty Street on August 22, 2002.
10 shared non-person entities · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
19 shared non-person entities · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗11 shared non-person entities · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.971 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Similarity score 0.951 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000096676
Part III of an air monitoring plan for remediation and deconstruction at 30 Warren Street in January 2006.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095766
Part II of a permit application dated January 10, 2006 for air monitoring during remediation at 30 West Street.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155430
Technical correspondence addressing asbestos air sampling methodology and pump flow rate specifications.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153258
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
Similarity score 0.948 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 1 Liberty Plaza · 1 pages · confidence 0.00 · verify page 1
- 120 Greenwich Street · 1 pages · confidence 0.00 · verify page 8
- 4 Albany Street · 1 pages · confidence 0.70 · verify page 22
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
Similar indexed content
Similar indexed content
Similar indexed content
NYC-WTC_000162890
Technical discussion regarding discrepancies in NIOSH method flow rates and requirements for large sample volumes at 114 Liberty Street.
Similar indexed content