NYC 9/11 Public Portal Document

rf I TEM Asbestos (air) Count Sheet sample area analyzed B Client Name: Riverpoint, Inc. Job #: 201103187 Volume fliters): 666.0 Lab Sample #: 03 Filter Type / Filter Area: MCE 385 mm2 Client Sample #: 101008 Grid Opening Size: 0.01000 "I Received: 10/23/2001 07:30:00 Area Examined: 0.10000 mm2 Date Analyzed: 10/24/2001 Magnification: 20,000 Scone #: Accelerating Voltage: 100 KeV Analysis Performed by: Mikhail Gruzman Grid Length Width Location Opening Fiber /iM gM Fiber Type Morphology EDS Orient. SAED Photo

E3-B4/6 1 NSD u E3-C4/6 2 NSD u u E3-E4/6 3 NSD u E3-F4/6 4 NSD u E3-G4/6 5 NSD u E3-H4/6 6 NSD u E3-K4/6 7 NSD u E4-F4/6 8 NSD u E4-G4/6 9 NSD u E4-H4/6 10 NSD u

u

i J

NSD: No Asbestos Structures Detected Comments Modified TEM Level II reports only asbestos fibers >=5 microns in length Structure Density Concentration (str/mm2) (str/cc air) Grid Evaluation Total Grid Openings: 10 Chrysotile Asbestos Structures; 0 <10 <0.0058 13 Grid Openings Covered >50% Amphibole Asbestos Structures: 0 <10 <0.0058 3 Intact Grid Opening > 50% <10 13 Undissolved Filter <10% Asbestos Structures >=5 microns: 0 <0.0058 Total Non-Asbestos Structures: 3 Folded Replica < 50% -'I Total Asbestos Structures: 0 <10 <0.0058 3 Filter Loading < 10% ! 3 Particulate Even Analytical Sensitivity: 10 0.0058

CITY_21MC100_008880378

NYC-WTC_000231562

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000231562Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →