I I TEM Asbestos (air) Count Sheet sample area analyzed

Client Name: Riverpoint, Inc. Job#: 201103187 Volume niters): 720.0 Lab Sample #; 02 Filter Type / Filter Area: MCE 385 mm2 Client Sample #: 051007 Grid Opening Size: 0.01000 Received: 10/23/2001 07:30:00 Area Examined: 0.10000 mm2 Date Analyzed: 10/23/2001 Magnification: 20,000 Scope #: Accelerating Voltage: 100 KeV Analysis Performed by; Aleksandr Barengolts Location Grid Fiber Length Width Morphology Opening /tM gM Fiber Type EDS Orient. SAED Photo E1.6/4C E1-6/4E 1 2 NSD NSD □U E1-6/4F 3 NSD U E1-6/4G 4 NSD U E1-6/4H 5 NSD U E2-4/3C 6 NSD u E2-4/3E 7 NSD u riI E2-4/3F 8 NSD u E2-4/3G 9 NSD u E2-4/3H 10 NSD u

A 1 )

I U "1

I NSD: No Asbestos Structures Delected -1 Comments Modified TEM Level 11 reports only asbestos fibers >=5 microns in length Structure Density Concentration (str/mm2) (str/cc air) Grid Evaluation Total Grid Openings: 10 <0.0053 13 Grid Openings Covered > 50% Chrysotile Asbestos Structures: 0 <10 13 Intact Grid Opening > 50% ■■ 1 Amphibole Asbestos Structures: 0 <10 <0.0053 3 Undissolved Filter < 10% Uj Asbestos Structures >=5 microns: 0 <10 <0.0053 [3 Folded Replica < 50% Total Non-Asbestos Structures: <0.0053 3 Filter Loading < 10% Total Asbestos Structures: 0 <10 Analytical Sensitivity; 10 0.0053 3 Particulate Even

CITY_21MC100_008880377

NYC-WTC_000231561

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000231561Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →