NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1848
Lab Group #: 7603 Filter Type / Filter Area: MCE 385
Lab Sample #: 3 Grid Opening Size: 0.01124
Client Sample #: 06 Area Examined: 0.04496 mm-
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 5/1/02
Analysis Performed By:
ROMAN PEYSAKHOV
GO. Structure Structure Type Length ID of Structure N or EDS
(Nonadb
No F 8 C M >=05 p >=5p Ctirys Amphibole Nonasb Ambig/ND
No Coord <5p Elements)
4 2
?
iF'-
Struct = > 0.5)j. > 5; 1 Aspect Ratio Grid acceptance:
-7= Positive diffraction pattern properties confonning to <50% undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% F B C M >5p
EDS spectrum confonning to laboratory holes or opaque areas
identification criteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos
T remolite
M = Matrix Non-Identified
Actinolite
NSD = No Structures Detected
CONFIDENTIAL, CITY_21MC100_001898243
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000230416
OCR can misread numbers and units. Confirm readings against the page image before using them.