NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume fliters): 1928
Lab Group #: 6673 Filter Type / Filter Area: MCE 385 mm-'
Lab Sample #: 13 Grid Opening Size: 0.01124
Client Sample #: 13 Area Examined: 0.04496 mm^
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 2/14/02
Analysis Performed By:
MARK PEYSAKHOV
GO. . Structure Structure Type ■ Length ID of Structure NorV EDS
(Nonadb
, No F B C M >=06 pi Chrys Amphibole Nonasb Ambig/ND
No Coord <5p Elements)
Z
Struct = > 0.5p .>, 5:1 Aspect Ratio Grid acceptance:
yl= Positive diffraction pattern properties conforming to "50% undissolved filter, overlapped or folded TotiUs
laboratory identification criteria observed ":10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% F B C M >5tJ
■/= EDS spectrum conforming to laboratory holes or opaque areas
identification criteria observed Chrysotile
i AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite. - Ambiguous
] Anthophyllite Non-Asbestos
C = Cluster (>3 Intersections)
Tremolite
M = Matrix
Acbnolite Non-Identified
MED = No Structures Detected
CONFIDENTIAL, CITY_21MC100_003389074
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000230329