NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume /liters): 1960
L2ib Grouji^ 7185 Filter Type / Filter Area: MCE 385 mm’
Lab Sample #: 13 Grid Opening Size: 0.01124
Client Sample #: ■13 .Area Examined: 0.04496 mm’
GRID BOX: Magnification: 20,000
GRID IP: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 3/23/02
Analysis Performed By:
ROMAN PEYSAKHOV
GO. Structure Structure Type Length ID of Structure N or \ EDS
(Nonadb
No F B C M >=05 p >=5p Chrys Amphibole Nonasb Ambig/ND
No Coord <5u Elements)
if
/<
Struct = > 0.5p >5:1 Aspect Ratio Grid acceptance:
'J= Positive diffraction pattern properties conforming to <50% undissolved filler, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% F B C M >5u
>1= EDS spectrum conforming to laboratory holes or opaque areas
identification criteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite
Ambiguous
C = Cluster (>3 Intersections) Anthophyllits Non-Asbestos
I remolite
M = Matrix Non-Identified
Actinolite
NSD = No Structures Delected
CONFIDENTIAL, CITY_21MC100_003388668
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000230050