NYC 9/11 Public Portal Document
104 East 25th St., 10th Floor
New York. New York 10010
www.atc-enviro.com
212353 8280
Fax 212.353.8306
ASSOCIATES INC.
April 17,2002
Mr. Bernard P. Orlan
Director, Environmental Health & Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101 -4008
Re: Wipe Samples for Dioxins
Public School 234M
ATC Project No. 15-19125-0279
Dear Mr. Orlan:
ATC Associates Inc. (ATC) is pleased to provide this report of the results of the wipe samples
for polychlorinated dibenzo-p-dioxins (PCDDs)and dibenzofurans (PCDFs) collected on March
8 and 15,2002, at the referenced location. The New York City Board of Education (BOE)
requested these samples to evaluate possible contamination in the school building per the
recommendation of Environ Corp., consultant to the parents association..
SCOPE OF WORK
The samples were collected using gauze pads and hexane as a solvent. The pads and solvent
were provided and samples were analyzed by Pace Analytical Services, Inc. (Pace) of
Minneapolis, MN, a laboratory experienced in dioxin analysis. The analysis was performed by
modified EPA Method 8290 using combined capillary column gas chromatography/high
resolution mass spectrometry.
Wagdi Abdelshahid, Industrial Hygienist of ATC’s New York City office, collected the samples.
The sampling was performed consistent with generally accepted industrial hygiene practices.
There were inherent limitations created by constraints of time, operational and work practice
variability, variations in contaminant concentrations, and sampling and analytical accuracy. The
results of the sampling represent conditions found on the date the samples were collected.
RESULTS
ATC submitted two (2) wipe samples, collected on each day, for PCDDs/PCDFs to Pace for
analysis. Copies of the laboratory analysis reports are provided in the Attachment. Samples
were taken from areas specified by the parents association consultant. The area of each sample
one (1) square meter (1 m2).
The New York State Department of Health (NYSDOH) established guidelines for dioxin for the
re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH
guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m^).
CITY_21MC100_002922090
NYC-WTC_000226273