NYC 9/11 Public Portal Document CITY 21MC100 002895524 ATC ASSOCIATES, INC. INDOOR AIR QUALITY FIELD REPORT Time: 9,07 LOCATTON: 90 Triniy Place AS for Leaderhlip and publie services DATB: S/8/02 Location Occupants Temperature CF) Relative Carbon Carbon Humidity Dioxide Monoxide (%) Hallway ouTsIDE #713 (ppm) (ppm) 4 772 771 419 483 1 Room+ 713 Room# 60г Roomi 613 STAIR CASE ALTO ST9 Floof Room# 505 Room# 506 R0Gm# 515 Room # 509 STAIRCASÉ 'À' TO 4H5 FLOUR Guideline levels ASHRAE/AIHA 41.9 455 3 22 8 771 777 77.2 76:8 76.6 76-6 76.6 26-4 68 - 75 F/winter 73-79 °F/summer 427 565 43.0 500 42.6 496 42.5 596 41.9 524 486 42-3 418 30-60% 529 593 Outdoor level +700 ppm Page 6 of 14_ Comments: PROJECT NO: 15-19125-0290 Respirable Particulate TVOCs (ppm) s (ug/m) 6 0.0 8 7 8 9ppm 65 ug/m" The assessed location(s) () Does () Does not meet established indoor air quality guidelines. Signature:_ Date: 51802 0'0 0. 0 0.0 0 0 0 0 0•0 0°0 0.0 1ppm NYC-WTC_000226250

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000226250Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000180206

ATC Associates indoor air quality field report for 90 Trinity Place documenting environmental conditions in May 2002.

Similar indexed content

NYC-WTC_000180169

ATC Associates indoor air quality field report for 90 Trinity Place detailing temperature, humidity, and pollutant levels in March 2002.

Similar indexed content

NYC-WTC_000180033

Field report form documenting indoor air quality measurements taken at a school in May 2002.

Similar indexed content

Compare copies and versions →