OCR status: ocr · source: ours

NYC 9/11 Public Portal Document CITY 21MC100 002895528 ATC ASSOCIATES, INC. Page 10 of_14 INDOOR AIR QUALITY FIBLD REPORT Time:)•10PM LOCATION: 90 Trinity Place /HS for Leadership and public services DATE: 5/802 PROJECTNO: 15-19125-0290 Location Occupants Temperature (F)* Relative Carbon Humidity (%) Dioxide (ppm) Carbon Monoxide (ppm)) Respirable Particulate 6(ug/m) 4 TVOCS (ppm) Roou # 1115 Room# 1109 Roou + 1105 Roau t 1106 STARWELLA'TO 10t9 Floor Room + 1003 Roaust 1006 Roam# 1005 Roomt 1015 Hallway octside + 1005 Guideline levels ASHRAE/AIHA 3 4 76:3 M3.2 924 0.0 756 42-0 802 • ' 1 75-4 417 849 0.0 74.9406 741 8 14.5 413 8/1 ( 12 12 14 758 44.1 960 191 426 924 0.8 0.0 0-0 00 15-5 44° 908 15-8 44.4 987 151 417 68-75°F/winter 30-60% $20 Outdoor level 10 24 14 13 16 9 ppm 65 ug/m 00 0 . 0 1 ppm 73-79 °F/summer + 700 ppm Comments: The assessed location(s) () Does () Does not meet established indoor air quality guidelines. signature:12 Date: 5/8/02 NYC-WTC_000226254

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000226254Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000180206

ATC Associates indoor air quality field report for 90 Trinity Place documenting environmental conditions in May 2002.

Similar indexed content

NYC-WTC_000180169

ATC Associates indoor air quality field report for 90 Trinity Place detailing temperature, humidity, and pollutant levels in March 2002.

Similar indexed content

NYC-WTC_000180033

Field report form documenting indoor air quality measurements taken at a school in May 2002.

Similar indexed content

Compare copies and versions →