FROM ; FAX Np: : Oct. 30 2001 02:30PM P4 I

TRACE ANALYTICS, INC. AirCheck ✓Report” Copyright© 2000 Trace Analylics, Inc. 15768 Hamilton Pool Road • Austin. Toxas 78738 voice; 800-AIR-1024 or 512-263-0000 • Fax; 512-263-0002 Customer No.: 95 E-mail: [email protected] . . , Report No.; 01-12673

Date Received; Tue, October 30. 2001 Compressed Air Systems Inc. Date Analyzed: Tue. October 30, 2001 Mr. Robert Miller, Jr. Date Reported; Tue, October 30, 2001 PO Box 567 Sampled By: Jeffrey W. Gouldey Buckingham PA 18912 Date Sampled; Fri. October 26, 2001 Air Source ID; Mako S/N 81-14-60-1

Sampled for Ground Zero .V

Results vs NFPA 1500-1997 & CGA G-7.1-1997 Grade 0(C) Air Quality Specification u . Concentration QC Results, %*

Limiting Characteristic Source Ambient Specification Accuracy Precision

Oxygen, Volume % 21.0 21,0 19.5-23.5 100 ■ 0.0

Nitrogen / Argon, Volume % 78.1 / 0.9 78.1 / 0.9 N/A / N/A 101 0.6

Carbon Monoxide (CO), ppmv <0.5 8.2 10 100 0.1 ■

"Carbon Dioxide (CO,), ppmv 372 413 1000 99 . 2.4 Water (H,O), ppmv/DewpoInt, °F <24/<-95 N/A 24/-65 (W) 105 4.5 Total TVHC (inclodlns CH.), ppiflV ■ 2'.2 4.8 N/A 100 0.4 Volatile Hydrocarbon Methane (CHJ, ppmv 2.2 2.4 N/A . 100 0.6 . Content (TVHC) TVHC <«clydlna CH.), PPmV ■ <0.6' 2.4 ■N/A N/A N/A OU (condensed) & Particulate, mg/m^ <0.04 N/A " 5 100 0.0 Odor (provided by customer) None/Slight ■ N/A None/Slight N/A N/A other N/A N/A N/A N/A N/A This sample COMPLIES with the above referenced specification.

Customer • Compressor Hours 537.72i Comments 'T E;-/c IwoW^CGA^Tl°1^rrat)f^N^F* br®’bVrT T N exfreme cold where m’oisrure can condense and freeze cauahgthe breathing apparatus to malfuncticn. a dew point not to exceed -65T Ppm W R O tie coWestteniperature eipecied In the is r«5Liired..." Dew pant is expressed tn °F at one atnxwere ' AT C E E S •ibisQCd^wasacquifeaMxhtfiesaniptesetwhicnincludeslhesampissfepoftedherein. /uxuracy relates observed to cwpeetedresUtel 100% is comple agreernent). P^.isiofi relates to reproducibirity (0.0% is complete aoreefnenO. At Trace Analytics, ino., calibrelion and QC aooouni fcf about 20% of anatysg Analytical Gases aVapos CAT-A-01 Gas Cnromatography/Mass Spectrometry Madia Source Botuc: 71lb75 Test • Oil & Rarsculate CAT-a-OS Analytical Gravimetiy sample Source Filter 107259 MethocS PartaeSize CAT-A-04 ■ Optical Microscopy Numoers Amttert Botue; 03621 Accredited Since 1991 By :»* American Association for Laboratory Accreditation A2LA Certificate No, 322.01

CITY_21MC100_008107430

NYC-WTC_000220276

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000220276Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000130038 · Box DEP Box 53

Chain of custody document from PSC Analytical Services regarding the receipt and analysis of samples for the DEP cleanup project.

Similar indexed content

Compare copies and versions →