4. Bundle — A structure composed of three or more fibers in a parallel arrangement with each fiber closer than one fiber diameter.

5. Clean area — A controlled environment which is maintained and monitored to assure a low probability of asbestos contamination to materials in that space. Clean areas used in this method have HEPA filtered air under positive pressure and are capable of sustained operation with an open laboratory blank which on subsequent analysis has an average of less than 18 structures/mm<2> in an area of 0.057 mm<2> (nominally 10 200-mesh grid openings) and a maximum of 53 structures/mm<2> for any single preparation for that same area.

6. Cluster — A structure with fibers in a random arrangement such that all fibers are intermixed and no single fiber is isolated from the group. Groupings must have more than two intersections.

7. ED — Electron diffraction.

8. EDXA -- Energy dispersive X-ray analysis.

9. Fiber — A structure greater than or equal to 0.5 am in length with an aspect ratio (length to width) of 5:1 or greater and having substantially parallel sides.

10. Grid — An open structure for mounting on the sample to aid in its examination in the TEM. The term is used here to denote a 200-mesh copper lattice approximately 3 mm in diameter.

11. Intersection — Nonparallel touching or crossing of fibers, with the projection having an aspect ratio of 5:1 or greater.

12. Laboratory sample coordinator — That person responsible for the conduct of sample handling and the certification of the testing procedures.

13. Filter background level — The concentration of structures per square millimeter of filter that is considered indistinguishable from the concentration measured on a blank (filters through which no air has been drawn). For this method the filter background level is defined as 70 structures/mm<2>.

14. Matrix — Fiber or fibers with one end free and the other end embedded in or hidden by a particulate. The exposed fiber must meet the fiber definition.

15. NSD — No structure detected.

16. Operator — A person responsible for the TEM instrumental analysis of the sample.

17. PCM — Phase contrast microscopy.

18. SAED -- Selected area electron diffraction.

19. SEM — Scanning electron microscope.

20. STEM — Scanning transmission electron microscope.

21. Structure — a microscopic bundle, cluster, fiber, or matrix which may contain asbestos.

22. S <3> — Structures per cubic centimeter.

http;//lexis/research/retrieve? rn=el35f2ca3d266867e53d261df3205722&_fmtstr=FULL<S... 02/04/2002 CITY_21MC100_012558666

NYC-WTC_000219926

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000219926Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →