NYC 9/11 Public Portal Document
TEM Asbestos fair) Count Sheet
Client Name: WC BOE Volume (liters): 1899
Lab Group #: 6015 Filter Tvpe / Filter Area: MCE 385 mm-
Lab Sample #: 18 Grid Opening Size: 0'01124
Client Sample #: 18 Area Examined: 0.04496 mm-
GRID BOX: Magnification: 20,000
GRIDED: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 12/1/01
Analysis Performed By:
ROMAN PEYSAKHOV
GO. Structure Structure Type Length ID of Structure N or EDS
No (Nonadb
F B C M >=0571 i>=5|j Chrys Amphibole Nonasb Ambig/ND
No Coord <5u Elements)
' 7
7 6/
Struct = > 0.5u .>5:1 Aspect Ratio Grid acceptance:
Positive diffraction pattern properties conforming to <50% undissoived filter, overlapped or folded Totals
Iaborato7 identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or oveifapped grid squares <5% F B C M ■ >5u
'/= EDS spectrum conforming to laboratory holes or opaque areas
identification criteria observed Clirysotile
: AMPHIBOLES Amphibole
F = Single Fiber 1 Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous I
C = Cluster (>3 Intersections) Anthophyllite
Tremolite
Non-Asbestos i
M = Matrix Actinolite Non-Identified
NSD = No Structures Detected
CITY_21MC100_000462030
NYC-WTC_000213290