2. The authority to stop work for non-compliance with the Scope of Work.

3. The authority to give technical direction to the contractor in the performance of the work.

4. The authority to review and approve or disapprove of the qualifications of the cleaning personnel involved in the work.

5. The right to inspect and accept or reject any work .

C. Qualifications Proof of qualifications must be presented upon request, including qualifications for wipe sampling, personal monitoring and HVAC evaluations.

Project Monitors The Project Monitors must possess valid NYS Asbestos Project Monitor certificates. The Project Monitors must have served as a third party project monitor on at least 20 asbestos abatement projects. Project Monitor must have performed final clearance inspections on at least 50 asbestos abatement projects. The Project Monitor must have access to translation services to schedule pre-cleaning unit inspections with residents.

Air Monitoring Technicians Air monitoring technicians must possess valid NYS Asbestos Project Sampling Technician (APST) certificates. Technicians must have performed air sampling for at least 6 months.

HVAC System Inspectors HV AC assessments and cleanliness inspections shall be conducted by qualified personnel. At a minium such personnel shall have an understanding ofHVA.C system operation and experience in utilizing accepted indoor environmental sampling practices, current industry HVAC cleaning procedures, and applicable industry standards.

Background Investigations All contractors and subcontractors involved in the monitoring activities at residential buildings under this contract are responsible for completing a background check on their employees prior to employees beginning on-site work and for screening unacceptable candidates from the pool of on-site workers. Contractors are required to maintain records ofbackground checks for 4 years and to make them available to the DEP and EPA when requested. At a minimum, the background check must include: 1. Law enforcement checks (5 years) 2. Professional license and certification

D. Specifications

2

CITY_21MC100_000439006 NYC-WTC_000209481

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000209481Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000140537 · Box DEP Box 05

Draft scope of work document detailing compliance requirements and procedures for residential cleaning and air sampling south of Canal Street.

Similar indexed content

Compare copies and versions →