Polynuclear Aromatic Hydrocarbons OSHA has taken 110 samples (excluding blanks). The majority of the samples have not shown the presence of benzo(a)pyrene and/or one or more of five additional fused polycyclic hydrocarbons: anthracene, acridine, pyrene, chrysene and phenanthrene. Sample results to date have identified eight samples which reached or exceeded OSHA’s coal tar pitch volatile PEL of 0.2mg/m’. These personal samples were taken on the pile on iron workers and grappler operators. OSHA continues to recommend the use of respiratory protection when working in the debris field. Freon R-22, Hydrogen Fluoride & Phosgene: OSHA has taken a total of 208 samples for Freon R-22 (chlorodiflouromethane), hydrogen fluoride, and phosgene. Only one Freon sample resulted in a detectable level of 6.4 ppm during the transfer of Freon from the auxiliary chiller, and all other samples were none-detected. OSHA does not have an exposure limit for Freon R-22. (The NIOSH REL for Freon is lOOOppm..) Sampling for the decomposition products of Freon R-22, hydrofluoric acid (HF) and phosgene showed no detectable levels.

Inorganic Acids OSHA has taken approximately 129 samples for inorganic acids such as hydrochloric, phosphoric, and sulfuric acids. Three samples for sulfuric acid were found to exceed OSHA’s permissible exposure limit (PEL) of 1 mg/m’. Workers were sorting debris.

Oxides of Nitrogen/ Sulfur: Sampling of grappler operators on the rubble pile, and on employees at the truck wash stations revealed trace levels of nitric oxide and nitrogen dioxide. SOj personal and area results were foimd to be below OSHA limits.

Metals: OSHA has taken a total of 1071 samples (excluding bulk and blank samples) to monitor worker exposures to dusts, fumes, oxides, and other compounds of metals such as antimony, beryllium, chromium, cobalt, copper, iron, lead.

Page 3 of 4

CITY_21MC100_002843820

NYC-WTC_000209197

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000209197Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →