NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

NYC-WTC_000209195

Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000209195–000209198
Page image
Scanned page image, NYC-WTC_000209196
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

exceeded the PEL. The highest sample result was approximately twenty-one times the OSHA limit (jack hammering concrete 16 feet below grade). The other elevated exposures were approximately one to fourteen times the OSHA limit. These exposures occurred during: 1) pre-drilling /slurry wall 2) jack hammering, 3) rubble removal and loading operations near the Winter Garden; 4) during the breaking up of concrete in the pit; 5) while drilling the concrete slurry wall, 6) flagging operations in pit, and 7) while chipping concrete with power tools during demolition activities at 7 WTC’s parking garage. Most of the work areas where apparent overexposures to silica occurred were in the rubble pile/pit; an area where OSHA continues to encourage the use of respiratory protection. Organic Compounds: OSHA has taken a total of 650 samples (excluding bulk and blank samples) for organic compounds such as acetaldehyde, acrolein, acrylonitrile, benzene, 2- butanone, carbofurans, dioxin, PCBs, ethyl benzene, formaldehyde, Freon R-22 (chlorodiflouromethane), hexone, isocyanates (e.g. MDI, TDI), perchloroethylene, polynuclear aromatics, phosgene, styrene, toluene, 1-3 butadiene, trichloroethylene, vinyl chloride, glutaraldehyde, and xylene. Screening samples initially showed elevated levels of some organic chemicals resulting from the fires burning in the rubble pile. Subsequent personal and area samples show worker exposure levels to be below OSHA limits. However, one personal sample result for a benzene sample taken was found to be at the 8-hr. OSHA Allowable Limit concentration of 1 ppm. This was found on a backhoe operator moving debris on 10/7/01. See information below for the specific counts in regards to polynuclear aromatics. Freon R-22, phosgene and dioxin.

Dioxins: OSHA has taken 10 dioxin samples (excluding blanks) in the plume over hot spots in (and around the perimeter of) the rubble pile. Dioxin levels detected around the perimeter are lower than those found directly over the pile. To date, only one sample taken on the rubble pile showed dioxin levels which exceeded background levels. Dioxins are considered collectively as suspect human carcinogens. OSHA does not have a PEL for dioxins.

Page 2 of 4

CITY_21MC1OO_OO2843819

NYC-WTC_000209196

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000209196Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →