4 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200056
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000200056–000200060
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
a?
Taylor environimeimtal grour inc. R Stuyvesant High School Chambers Street, New York, NY SCA Project #:M477-15217, LLW#: 29881
Auditorium Carpet Removal / Chair Upholstery Cleaning Protocol Revised August 23, 2002 Revision #2 R 1. Shut down the heating, ventilation, and air-conditioning (HVAC) system(s) for the auditorium.
2. Attached personal/waste decontamination unit(s) will be constructed and located at the main entrance (s) to the auditorium (work area). Full enclosure(s) shall be constructed to enclose all carpeted floor surfaces within the auditorium. The full enclosure(s) shall be constructed using a framework consisting of 2inch x 3 inch. studs. (36 inch. O.C.) lined with 2 layers of 6-mii plastic sheeting.
3. Negative pressure ventilation equipment will be installed inside the full enclosure(s) in order to establish a minimum static negative-pressure differential of 0.02 inches water column.
4. All penetrations that can be reached using an 8 foot ladder (such as windows, doorways, supply air diffusers, return air grilles, etc.) shall be sealed with 2 layers of 6-mil plastic sheeting sealed with tape.
5. A thorough visual inspection will be performed by a third party consultant to verify that all required engineering controls are in place and working correctly.
6. Clean the chair upholstery and associated floor surfaces twice using HEPA filtered vacuum equipment.
7. After the chair upholstery and associated floor surfaces have passed a thorough visual inspection, all seating systems shall be covered with two layers of 6-mil
c plastic sheeting and sealed with tape.
8. All carpeted floor surfaces within the full enclosure(s) shall be saturated with an approved lock-down encapsulant and then covered with two layers of 6-mil plastic sheeting sealed with tape.
9. The plastic covered carpet shall be continually misted with amended water while it is being cut into manageable sections and rolled up. When a section of carpet has been rolled up, it shall be misted with amended water ands sealed with two layers of 6-mil plastic sheeting. The sealed carpet section shall be transported to the
I ! 130A JERICHO TPKE., FLORAL PARK, NY 11001- PHONE (516) 358-2955 ■ FAX (516) 358-1780
CITY_21MC100_001825040 NYC-WTC_000200059
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
No available related records indexed in this group.
Filed elsewhere
NYC-WTC_000155880
Document outlining requirements for a consultant to provide full-time asbestos air monitoring during the interior cleaning of 125 Cedar.
3 shared non-person entities · 1 shared topics · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗3 shared non-person entities · 1 shared topics · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗3 shared non-person entities · 1 shared topics · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗3 shared non-person entities · 1 shared topics · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗4 shared non-person entities · 1 shared topics · similarity 0.928
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107169
Letter from DEP responding to an inquiry by enclosing scopes of work for environmental cleanup at 125 Cedar Street.
5 shared non-person entities · 1 shared topics · similarity 0.928
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107379
Formal request by a resident for the Department of Environmental Protection to perform cleaning and monitoring work at their apartment.
5 shared non-person entities · 1 shared topics · similarity 0.928
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160257
Extensive EPA-distributed memo coordinating federal, state and local agency response to World Trade Center environmental issues.
5 shared non-person entities · 1 shared topics · similarity 0.927
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156006
Internal communication confirming receipt of Department of Health mold assessment report for 125 Cedar.
5 shared non-person entities · 1 shared topics · similarity 0.927
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138892
Forwarding draft cleaning procedures for 114 Liberty Street to EPA for review and comments.
4 shared non-person entities · 1 shared topics · similarity 0.926
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000147533
A draft letter from the Department of Education acknowledges DEP's concurrence with EPA and DOH recommendations for carpet removal at affected schools.
Similarity score 0.938 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.938 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000159742
Emails coordinating the drafting of a support letter from DEP to validate carpet removal efforts for FEMA reimbursement.
Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000159758
Emails coordinating the drafting of support letters from the EPA and DEP to validate carpet removal efforts for FEMA reimbursement.
Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
NYC-WTC_000155880
Document outlining requirements for a consultant to provide full-time asbestos air monitoring during the interior cleaning of 125 Cedar.
Similar indexed content
Similar indexed content
Similar indexed content
Similar indexed content