Controls • Confined space entry procedures • Respiratory protection for workers in the inner zone and for specific tasks, such as concrete work and torch cutting. • Good torch cutting practices: using long torches, keeping head out of the plume, wearing respirator.

Controls (Continued) • Hearing protection for pneumatic hammer operation, concrete cutting, etc. • Wet methods for concrete work • Elevated exposure feedback loop

Future Sampling Strategy • Emphasis On: - Silica during concrete work - Metals during torch cutting - Carbon Monoxide - more work now being done on lower levels - Noise - more work now on concrete demo

8

CITY_21MC100_003051034

NYC-WTC_000199690

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000199690Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000132576 · Box DEP Box 54

A letter from Capital Properties submitting additional air quality monitoring results for Broadway and Trinity Place buildings to the DEP.

Similar indexed content

Compare copies and versions →